{"product_id":"hikvision-wired-photoelectric-smoke-detector-with-built-in-sounder-ds-pdsmk-4bar","title":"Hikvision Wired Photoelectric Smoke Detector with Built-in Sounder – DS-PDSMK-4BAR","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHikvision DS-PDSMK-4BAR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a conventional wired photoelectric smoke detector designed for early smoke detection and audible alarm notification in residential and commercial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt uses an advanced \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ephotoelectric smoke sensing chamber\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to provide reliable smoke detection with high immunity against unwanted alarms. The detector operates on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4-wire, 12V DC system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and includes an alarm relay output configurable as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNormally Open (N\/O) or Normally Closed (N\/C)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike the standard DS-PDSMK-4, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDS-PDSMK-4BAR includes a built-in sounder rated at ≥85 dB at 3 meters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and supports an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic reset function with a reset time of 28–35 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Dual red LEDs provide 360° visual alarm indication. \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eWired \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ephotoelectric smoke detector\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eConventional \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNon-Addressable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e design\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e4-wire\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e connection\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eBuilt-in sounder: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e≥85 dB @ 3 m\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic reset function\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eAuto reset time: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e28–35 seconds\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSmoke alarm threshold: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.10–0.16 dB\/m\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSampling interval: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8 seconds\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eDual red LEDs for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e360° alarm visibility\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSPST alarm relay\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eSelectable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eN\/O or N\/C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e relay output\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRelay rating: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1A @ 30V DC \/ 0.5A @ 125V AC\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOperating voltage: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10.2–13.8V DC\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLow standby current: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e≤60 μA\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEasy installation with no programming required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePhotoelectric chamber designed for high immunity against unwanted alarms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eCE approved \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWired Smoke Detector with Sounder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDetection Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotoelectric Smoke Detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConventional \/ Non-Addressable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWiring\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.2–13.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStart-Up Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤200 μA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStart-Up Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤60 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandby Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤60 μA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Alarm Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Permitted Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSampling Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSmoke Alarm Threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.10–0.16 dB\/m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eObscuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.51–2.73% \/ ft\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Sounder\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSound Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥85 dB @ 3 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlarm Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPST – N\/O or N\/C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelay Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1A @ 30V DC \/ 0.5A @ 125V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuto Reset\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuto Reset Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28–35 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReset Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReset Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlarm Indicator\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Red LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDS-PDSMK-4BAR\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose Hikvision DS-PDSMK-4BAR?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe DS-PDSMK-4BAR combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esmoke detection, audible warning and visual indication in one device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its integrated ≥85 dB sounder means the detector can provide an immediate local audible warning when smoke is detected.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompared with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDS-PDSMK-4\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this BAR version adds both the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt-in sounder and automatic reset function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it the more feature-rich option when local audible notification is required. \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"HIKVISION","offers":[{"title":"Default Title","offer_id":67635811025212,"sku":null,"price":35.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/2356\/2044\/files\/WhiteCeilingSmokeDetectorwithLens.png?v=1791301578","url":"https:\/\/bestways.com\/products\/hikvision-wired-photoelectric-smoke-detector-with-built-in-sounder-ds-pdsmk-4bar","provider":"Bestways Smart-home Solutions ","version":"1.0","type":"link"}